Vista de pagina 14
WIRING DIAGRAM
24Vac Out
to Heater
24Vac Power
Supply Output
24Vdc Out
to Blower
24Vac Power
Supply Input
Ground
Ground
(B+)
(Ground)
J3
J6
J4 J5
J1
24 Vac
* HEATER AND BLOWER
HOUSING KIT SPECIFICATIONS
5.5(14)
2.5(6.4)
2.3(5.9)
20.5(52.02)
9.68(24.6)
Unit: inch(cm)
Camera Housing Window Size 2.5" W x 2.3" H (6.4cm x 5.9cm)
Camera Housing Construction Die-cast, extruded, and sheet aluminum
Camera Housing Finish
Light-gray ployester powder coat
Wall Bracket Pan Adjustment 360
Wall Bracket Tilt Adjustment
70
Wall Bracket Locking Method
4 holes for fasteners of a suitable size & type.
Mount to a secure solid surface.
Total Dimension(WxHxL)
5.5" W x 9.68" H x 20.5" D
(14cm x 24.6cm x 52.02cm)
Total Weight
9.15Ib( 4.15kg)
- 10 -